摘要: 冰箱外部凝露是消费者关注度较高的问题之一。本文以十字对开多门风冷冰箱为载体,从冰箱门体凝露的凝露机理入手,并通过试验验证:增大防凝管与竖梁接触面积,改善门封密封绝热,增强把手导热,同时优化风循环控制规则,多种方案组合使载体冰箱满足32℃,85%相对湿度外部凝露要求。

关键词: 风冷冰箱, 多门冰箱, 外部凝露, 凝露机理, 防凝露

Abstract: The external condensation of refrigerator is always be concerned highly by consumers. This article is starting with condensation mechanism to discuss about the several schemes that can meet the external condensation requirement of 32℃ and 85% RH humidity environment. These schemes that based on multi-door frost-free refrigerator are validated though kinds of possible methods like: increasing contact area of anti-condensation pipe and the vertical beam, improving thermal isolation of the door gasket, strengthening heat conduction of the handle, or optimizing the intensity of air convection, meanwhile, combining these methods together.