Journal of Appliance Science & Technology ›› 2023, Vol. 0 ›› Issue (1): 30-33.doi: 10.19784/j.cnki.issn1672-0172.2023.01.003

• Articles • Previous Articles     Next Articles

Study on the influence of air deflector on air volume and indoor air distribution of air conditioning

ZHANG Hengqing1, YANG Jie1, CHEN Chao2, YAN Jianfang2   

  1. 1. College of Mechanical and Electrical Engineering, Qingdao University Qingdao 266071;
    2. Hisense Air Conditioning Co., Ltd. Qingdao 266071
  • Online:2023-02-01 Published:2023-04-24

Abstract: Using the computational fluid dynamics software Star-CCM+, the indoor air flow of the four side air outlet embedded air-conditioning air deflector at different angles is numerically simulated, and the air volume of each outlet and the overall air volume are calculated. The numerical relationship between the angle of the air deflector and the air volume is obtained by using the numerical fitting method of MATLAB, and the quintic polynomial can accurately describe the relationship between the air volume and the static angle; Through the simulation of the velocity field and temperature field of the 1.5 m height plane, it is concluded that the indoor air flow can better meet the comfort requirements when the air deflector is at 40°.

Key words: Air deflector, Indoor unit of air conditioner, Flow and heat transfer simulation, Indoor air distribution, Comfort

CLC Number: