家电科技 ›› 2022, Vol. 0 ›› Issue (5): 44-49.doi: 10.19784/j.cnki.issn1672-0172.2022.05.006

• 论文 • 上一篇    下一篇

北京市春季居室内生物污染特征及影响因素分析

张庆玲1, 冯素梅1, 姚艳春1, 刘颖2, 王统帅1, 赵金丹1   

  1. 1. 中国家用电器研究院 北京 100053;
    2. 中家院(北京)检测认证有限公司 北京 100176
  • 出版日期:2022-10-01 发布日期:2022-11-01
  • 作者简介:张庆玲(1987—),女,硕士学位,工程师。研究方向:环境与健康相关产品检测。E-mail:zhangql@cheari.com。

Analysis on the characteristics and influencing factors of indoor biological pollution over Beijing in spring

ZHANG Qingling1, FENG Sumei1, YAO Yanchun1, LIU Ying2, WANG Tongshuai1, ZHAO Jindan1   

  1. 1. China Household Electric Appliance Research Institute Beijing 100053;
    2. CHEARI (Beijing) Certification & Testing Co., Ltd. Beijing 100176;
  • Online:2022-10-01 Published:2022-11-01

摘要: 为调查北京市春季居室环境内生物污染情况,2017年3月—4月对32个居民家庭室内灰尘进行了连续5周采样,运用酶联免疫吸附法和倾注平板法分别检测了过敏原和微生物浓度,探讨了喂养宠物、家具使用和环境温湿度对生物浓度的影响。结果表明,过敏原中粉尘螨过敏原Der f1浓度明显高于屋尘螨过敏原Der p1浓度(P<0.001),均值分别为74.91 ng·g-1和13.45 ng·g-1。微生物中细菌浓度明显高于真菌浓度(P<0.001),均值分别为3.06×106 CFU·g-1和5.77×103 CFU·g-1。相关性分析表明,床的使用人年龄与细菌浓度呈显著负相关(P<0.01),温度与细菌浓度、真菌浓度均呈正相关(P<0.05),细菌和真菌间存在正相互作用(P<0.05),其他因素与过敏原、微生物浓度没有相关性。研究显示,北京市居室环境内生物污染物主要为粉尘螨过敏原Der f1和细菌,温度对微生物浓度影响较大。

关键词: 居室环境, 生物污染, 浓度特征, 影响因素

Abstract: In order to investigate the biological pollution in the indoor environment over Beijing in spring, the indoor dust samples of 32 households were sampled for 5 weeks from March to April 2017. The concentrations of allergens and microorganisms were detected by enzyme-linked immunosorbent assay and pour plate method, respectively, and the effects of feeding pets, furniture usage, and environmental temperature and humidity on the biological concentrations were discussed. The results showed that from March to April 2017, the concentration of Der f1 allergen in the indoor environment of Beijing was significantly higher than that of Der p1 (P<0.001), with the mean values of 74.91 ng·g-1 and 13.45 ng·g-1, respectively. The bacterial concentration was significantly higher than the fungal concentration (P<0.001), with the mean values of 3.06×106 CFU·g-1 and 5.77×103 CFU·g-1. The correlation analysis showed that the age of the user of the bed was significantly negatively correlated with the bacterial concentration (P<0.01), the temperature was positively correlated with the bacterial concentration and fungal concentration (P<0.05), and there was a positive interaction between bacteria and fungi (P<0.05). Other factors have no correlation with the concentration of allergens and microorganisms. The study shows that the main biological pollutants in the residential environment in Beijing are the dust mite allergen Der f1 and bacteria, and temperature has an effect on the concentration of microorganisms.

Key words: Indoor environment, Biological pollution, Concentration characteristics, Influencing factors

中图分类号: