Journal of Appliance Science & Technology ›› 2019, Vol. 0 ›› Issue (5): 68-70.doi: 10.19784/j.cnki.issn1672-0172.2019.05.007

• Articles • Previous Articles     Next Articles

Simulation analysis and experimental study on heat dissipation of electronic component for air conditioner outdoor unit

LI Shuyun, PENG Guangqian, WU Junhong   

  1. Gree Electric Appliances, Inc. of Zhuhai Zhuhai 519070
  • Online:2019-10-01 Published:2019-10-23

Abstract: Aiming at reducing the temperature of the electrical of air conditioner outdoor unit, the thermal analysis software was used to simulate the temperature field for air conditioner outdoor unit. According to the temperature distribution in the space where the electrical was located, a scheme was proposed that the opening was added to the bulkhead of the air conditioner outdoor unit, compared with the bulkhead without opening scheme. The results showed that the new scheme increased the air flow and reduced the temperature of the electrical well, the temperature of the electrical was reduced by 12.3℃ on average. Finally, the new scheme were verified by experiments, the results showed that the simulation was valid and reliable.

Key words: Air conditioner, Bulkhead, Opening, Electrical, Heat dissipation