Journal of Appliance Science & Technology ›› 2018, Vol. 0 ›› Issue (12): 43-45.

• Articles • Previous Articles     Next Articles

Analysis of short-circuit current for high voltage tester and 200mA verification method

PANG Cong, SUN Yanyan, WANG Chenkai   

  1. Panasonic Home Appliances R&D Center (Hangzhou) Co., Ltd.(PHARADH) Hangzhou 310018
  • Online:2018-12-01 Published:2019-07-08

Abstract: When conducting the electrical strength test of Chapters 13.3 and 16.3 of IEC 60335-1, the short-circuit and release energy requirements for the high-voltage power supply capacity of the equipment when the test voltage is≥4000V, the short-circuit current Is≥200mA, trip current Ir≥100mA. In the JJG 795 verification procedure, only Ir is verified, and Is is not verified, so the laboratory needs to master a method of verifying Is. This article understands Ir and Isfrom the working principle of the high voltage tester, and then introduces the methods of indirect verification and direct measurement of Is.

Key words: High voltage tester, High voltage transformer, Short-circuit current Is, Trip current Ir