Journal of Appliance Science & Technology ›› 2021, Vol. 0 ›› Issue (6): 42-44.doi: 10.19784/j.cnki.issn1672-0172.2021.06.005

• Articles • Previous Articles     Next Articles

Experimental study of the parallel flow heat exchanger in cabinet air conditioning

DAI Chuanmin1,3, TENG Zhaolong1,3, MA Qiang1,3, ZHANG Mingjie2,3   

  1. 1. Qingdao Haier Smart Technology R&D Co., Ltd. Qingdao 266103;
    2. Qingdao Haier Air Conditioner Gen. Corp. Qingdao 266103;
    3. State Key Laboratory of Digital Homehold Appliances Qingdao 266103
  • Online:2021-12-01 Published:2022-01-05

Abstract: Parallel flow heat exchanger has the advantages of small size, high heat transfer coefficient and less refrigerant charge in the system. It has a great application prospect in room air conditioner. A parallel flow indoor heat exchanger applied to 5 hp cabinet machine is designed. Through experimental test, the performance of air conditioner with parallel flow heat exchanger and ordinary tube fin heat exchanger is compared and analyzed, and the heating performance of air conditioner with parallel flow heat exchanger is optimized. The results show that compared with the ordinary tube fin heat exchanger, when the parallel flow heat exchanger is used, the refrigerating capacity is increased by 10.2%, but the heating capacity is reduced by 5.7%. After adding a flash evaporator in the system, its heating performance is slightly higher than that of tube fin heat exchanger.

Key words: Parallel flow heat exchanger, Flash evaporator, Tube fin evaporator, The system performance