Journal of Appliance Science & Technology ›› 2025, Vol. 0 ›› Issue (zk): 36-40.doi: 10.19784/j.cnki.issn1672-0172.2025.99.007

Previous Articles     Next Articles

Signal fusion in active noise control for range hoods

YIN Jiuchao1,2, ZHAO Chengyu1,2, YU Guitao1,2, ZHANG Xi1,2, GUO Zhongyuan1,2   

  1. 1. Ningbo Fotile Kitchen Ware Co., Ltd. Ningbo 315336;
    2. Healthy & Intelligent Kitchen Engineering Research Center of Zhejiang Province Ningbo 315336;
    3. University of Electronic Science and Technology of China Chengdu 611731
  • Published:2025-12-30

Abstract: To mitigate the operational noise of range hoods, it introduces an active noise control (ANC) method using multi-channel data fusion. This approach fuses signals from multiple reference sensors into a single input, creating a computationally efficient Single-Input Multiple-Output (SIMO) control system. This method not only maintains noise reduction performance but also enhances robustness against hardware variations. Experimental results show that, compared to a conventional MIMO system, our proposed method achieves equivalent noise reduction at the listener’s position with a 75% decrease in computational load. The technology has been successfully validated in commercial range hoods, proving its practical value for engineering applications..

Key words: Range hood, Active Noise Control (ANC), Data Fusion, Signal Processing

CLC Number: