Journal of Appliance Science & Technology ›› 2021, Vol. 0 ›› Issue (5): 145-147.doi: 10.19784/j.cnki.issn1672-0172.2021.05.028

• Articles • Previous Articles     Next Articles

Heat loss calibration device for domestic static heat pump water heater and method analysis

WANG Zhikun1, MA Anna1, YANG Shuang1, CAI Ning1, LI Hao1, XU Ling2, CHEN Jie2   

  1. 1. CHEARI (Beijing) Certification & Testing Co., Ltd. Beijing 100176;
    2. Chuzhou Technical Supervision and Testing Center Chuzhou 239000
  • Online:2021-09-01 Published:2021-10-12

Abstract: According to the requirements of the new version of GB/T 23137-2020 "Household and similar heat pump water heaters", a set of heat loss calibration system is designed. The system is mainly composed of calibration water tank, stirring pump, electric heating rod, power regulator, power meter, temperature protector, temperature measurement unit and data acquisition system. By testing and analyzing the thermal insulation performance, heat leakage and additional errors of the system, the test process is optimized and the accuracy of the water heater performance test is improved.

Key words: Heat pump water heaters, Calibration water tank, Thermal insulation performance, Heat leakage, Additional errors

CLC Number: