Journal of Appliance Science & Technology ›› 2022, Vol. 0 ›› Issue (zk): 470-474.doi: 10.19784/j.cnki.issn1672-0172.2022.99.103

Previous Articles     Next Articles

Optimization research of CFD in the inlet water channel of reverse osmosis membrane module

DU Yongtao1, WANG Ye1,2, LI Jian1, FAN Huiwu1   

  1. 1. Qingdao Haier Smart Technology R & D Co., Ltd. Qingdao 266101;
    2. State Key Laboratory of Digital Household Appliances Qingdao 266101
  • Published:2023-03-28

Abstract: Feed channel configuration within reverse osmosis (RO) membrane element greatly impacts the membrane fouling rate. Through analyzing four trending RO membrane, this paper summarized the membrane element with different feed channels. Computational fluid dynamics was used to simulate different flow channels, and their influences on parameters such as flow velocity, mass transfer efficiency and energy consumption were compared. The results showed that, when reducing water inlet and outlet widths, influent flow rate and wall shear stress was increased so that the membrane fouling rate was decreased.

Key words: Reverse osmosis membrane, Influent channel, Membrane fouling