Journal of Appliance Science & Technology ›› 2023, Vol. 0 ›› Issue (zk): 140-144.doi: 10.19784/j.cnki.issn1672-0172.2023.99.033

Previous Articles     Next Articles

Numerical simulation of the effect of soaking tank volume on constant temperature performance in gas water heater

ZHAO Ting1,2, WANG Longqiang1,2, YAN Chao1,2, BI Sanbao1,2   

  1. 1. Qingdao Haier Smart Technology R&D Co., Ltd. Qingdao 266101;
    2. State Key Laboratory of Digital Household Appliances Qingdao 266101
  • Online:2023-12-12 Published:2023-12-26

Abstract: Aiming at the insulation tank components in the gas-electric hybrid gas water heater, a collaborative method of numerical simulation and experimental verification was used to study the influence of the volume design of the soaking tank on the start-up constant temperature and secondary start-up constant temperature performance. It was analyzed that in the first start-up scenario, the small volume soaking tank had a larger overshoot temperature and a faster heating rate. In the secondary startup scenario, the small volume soaking tank has a higher overshoot temperature, which takes longer to reach the constant temperature, providing a reference basis for the design of the soaking tank in gas water heater.

Key words: Gas water heater, Soaking tank, Numerical simulation

CLC Number: