Journal of Appliance Science & Technology ›› 2021, Vol. 0 ›› Issue (zk): 2-4.doi: 10.19784/j.cnki.issn1672-0172.2021.99.001

    Next Articles

Experimental study of multi-split air conditioner on technology of condensation heat defrosting

DAI Chuanmin1,2, LAO Chunfeng1,2, WEI Wei1,2, MA Changming1,2, TENG Zhaolong1,2, SUN Ping1,2   

  1. 1. Qingdao Haier Smart Technology R&D Co., Ltd. Qingdao 266103;
    2. State Key Laboratory of Digital Household Appliances Qingdao 266103
  • Online:2021-11-25 Published:2021-12-22

Abstract: In the winter heating scenario, air source products often stop heating due to the defrosting of outdoor heat exchanger, which leads to the decrease of indoor temperature and poor user experience. Therefore, improving the comfort of indoor users during defrosting operation has become an important subject for air source heat pump. Outdoor heat exchanger is divided into two parts. By controlling the saturation temperature of the refrigerant and using the latent heat of the refrigerant, the effective alternate defrosting technology of heat exchanger is developed. The experimental results show that: 1. Effective defrosting is achieved with the lowest refrigerant flow at a defrost saturation temperature from 2℃ to 8℃. 2. Under the outdoor condition of 2℃, the average heating capacity of latent heat defrosting is 75% of the rated capacity.

Key words: Defrost, Continuous heating, Condensation heat, Refrigerant pressure, Heat exchanger