Journal of Appliance Science & Technology ›› 2023, Vol. 0 ›› Issue (6): 92-95.doi: 10.19784/j.cnki.issn1672-0172.2023.06.015

• Articles • Previous Articles     Next Articles

Research on the reliability and quality of air conditioning sponge adhesive quality

GUO Chunhui, SHAN Baodi, XIE Xiayang, CAI Limu, CHEN Jiacan, WANG Yu   

  1. Gree Electric Appliances, Inc., of Zhuhai Zhuhai 519070
  • Online:2023-12-01 Published:2024-04-17

Abstract: Sponge is widely used in air conditioning because of its good buffering, earthquake resistance, heat insulation, moisture-proof and chemical corrosion resistance. Focuses on the technical research of the sponge pasted in the air conditioner, and studies the factors affecting the reliability of the sponge pasted in the product under the standard working conditions. Based on Solidworks simulation study of sponge paste after the elastic finite element analysis, and based on the experimental research part structure influence on the reliability of the sponge paste, using single variable grey forecasting model of sponge paste in forecast analysis on the status of the different structure parts, and combining with the actual working condition of put forward on the paste process as well as front end design corresponding measures to prevent sponge case become warped fall off.

Key words: Air conditioner, Sponge, Turn up, Finite element analysis, Grey prediction

CLC Number: