Journal of Appliance Science & Technology ›› 2021, Vol. 0 ›› Issue (1): 16-19.doi: 10.19784/j.cnki.issn1672-0172.2021.01.001

• Articles • Previous Articles     Next Articles

Study on formaldehyde release and limit in refrigerator storage room

FENG Qiang1, SHEN Jian1, BO Xiaoqing1, LIU Guohai1, RAO Qinlong2, DOU Huimin1   

  1. 1. Hefei Midea Refrigerator Co., Ltd. Hefei 340100;
    2. Hefei University of Technology Hefei 340100
  • Published:2021-03-02

Abstract: Formaldehyde has a negative impact on human health. In order to study the formaldehyde release content and release law in the refrigerator storage room, the formaldehyde content of the refrigerator storage room under different sealing time, different positions, and different working conditions was measured and analyzed by the phenol reagent method. The results show that the formaldehyde content in the storage room will gradually increase and reach saturation with the extension of the closed time of the refrigerator. In the saturated state, the content of formaldehyde in the refrigerator compartment is the highest, the freezing lower compartment is the second, and the freezing upper compartment is the lowest. Among them, the proportions of formaldehyde emission from box bladders, door seals, drawer panels and foams are relatively high. In addition, based on the human health threshold, a comprehensive analysis of the limit of formaldehyde in the refrigerator was carried out, and it was recommended that its content should be less than 0.1 mg/m3.

Key words: Refrigerator, Formaldehyde, Limit study, Phenol reagent method