Journal of Appliance Science & Technology ›› 2025, Vol. 0 ›› Issue (4): 120-123.doi: 10.19784/j.cnki.issn1672-0172.2025.04.021

• Articles • Previous Articles     Next Articles

Case study and simulation model of the condensation of the wind deflector

LI Tongqin1, CHEN Shouhai2, QIU Ziyue1, WANG Xiangqian1, GONG Lianfa1   

  1. 1. Hisense Home Appliances Group Co., Ltd. Qingdao 266100;
    2. Hisense Air Conditioning Co., Ltd. Qingdao 266100
  • Published:2025-10-09

Abstract: When the household air-conditioner is running in the high humidity environment in summer, the condensation and dripping of the wind deflector occurs, which causes significant inconvenience to the user. In order to quantify the evaluation method of wind deflector condensation, proposes a wind deflector condensation simulation method based on dehumidification model, and carries out the wind deflector condensation prediction analysis of a certain model of home empty hang-up machine. The results show that the condensation simulation method used can predict the condensation location well, and the condensation dripping risk at the bottom of the guide plate can be greatly improved by optimizing the contour line at the bottom of the large guide plate and matching the design with the air duct contour line.

Key words: Dehumidification model, Condensation simulation method, Condensation location, Dew condensation rate

CLC Number: