家电科技 ›› 2025, Vol. 0 ›› Issue (zk): 241-245.doi: 10.19784/j.cnki.issn1672-0172.2025.99.050

• 第二部分 制冷与空调 • 上一篇    下一篇

热泵空调低温制热性能分析与验证

刘钊行1, 王晓倩1, 何振健2, 冯青龙2   

  1. 1.珠海格力电器股份有限公司 广东珠海 519070;
    2.珠海格力节能环保制冷技术研究中心有限公司 广东珠海 519070
  • 发布日期:2025-12-30
  • 作者简介:刘钊行,学士学位。研究方向:制冷空调产品研究与开发。E-mail:786848709@qq.com。

Analysis and verification of low-temperature heating performance of heat pump air conditioners

LIU Zhaohang1, WANG Xiaoqian1, HE Zhenjian2, FENG Qinglong2   

  1. 1. GREE Electric Appliances, Inc. of Zhuhai, Zhuhai 519070;
    2. Green Refrigeration Equipment Engineering Research Center of Zhuhai GREE Co., Ltd. Zhuhai 519070
  • Published:2025-12-30

摘要: 传统热泵空调在低温环境下使用存在频繁结霜除霜,导致连续运行制热性能大幅衰减,制约了热泵空调的推广应用。针对上述问题,从低温制热运行期间压缩机频率、电子膨胀阀开度及排气温度等系统参数,以及换热器管温变化对制热性能和结除霜情况的影响进行理论分析和实验验证,结果表明:低温制热性能的提升需要综合考虑压缩机运行频率、电子膨胀阀开度及换热器管温的影响;可以适当提高空调系统蒸发压力和蒸发温度,减弱室外换热器结除霜情况对低温制热性能的影响;在进入除霜前的运行阶段应避免电子膨胀阀开度不断关小使空调系统循环流量减小,进而加速系统低温制热性能衰减。

关键词: 热泵空调, 低温制热性能, 理论分析, 实验验证

Abstract: Traditional heat pump air conditioners experience frequent frosting and defrosting in low-temperature environments, leading to a significant decline in continuous heating performance, which restricts the promotion and application of heat pump air conditioners. In response to these issues, conducts theoretical analysis and experimental verification on the impact of system parameters such as compressor frequency, electronic expansion valve opening, and exhaust temperature during low-temperature heating operation, as well as the changes in heat exchanger tube temperature on heating performance and frosting/defrosting conditions. The results show that improving low-temperature heating performance requires a comprehensive consideration of the effects of compressor operating frequency, electronic expansion valve opening, and heat exchanger tube temperature; it is possible to appropriately increase the evaporating pressure and temperature of the air conditioning system to weaken the impact of outdoor heat exchanger frosting and defrosting on low-temperature heating performance; during the operation phase before entering defrosting, it should be avoided to continuously reduce the opening of the electronic expansion valve, which would decrease the circulation flow of the air conditioning system and thus accelerate the rapid decline of the system’s low-temperature heating performance.

Key words: Heat pump air conditioner, Low-temperature heating performance, Theoretical analysis, Experimental verification

中图分类号: