Journal of Appliance Science & Technology ›› 2021, Vol. 0 ›› Issue (zk): 351-354.doi: 10.19784/j.cnki.issn1672-0172.2021.99.083

Previous Articles     Next Articles

Optimal design of heat exchanger whistling sound with four side air outlet embedded air conditioner

ZHANG Guodong, CHEN Chao, CHENG Jun, YAN Jianfang, DAI Xianwei   

  1. Hisense (Shandong) Air Conditioning Co., Ltd. Qingdao 266000
  • Online:2021-11-25 Published:2021-12-22

Abstract: Finned heat exchanger is widely used in air conditioning. Its fins will form an open cavity. When the fluid passes through the cavity, it is easy to produce a high-frequency whistling sound, which affects the user experience. Aiming at the problem of heat exchanger whistling sound of an embedded air conditioner with four air outlets, the air duct flow field is numerically simulated, the causes of heat exchanger whistling sound are analyzed, the spoiler is designed to optimize the heat exchanger whistling sound, and the noise experiment is carried out in the semi anechoic noise room. The effectiveness of heat exchanger whistling sound improvement is explained from the spectrum and subjective evaluation.

Key words: Numerical simulation, Spoiler, Heat exchanger whistle

CLC Number: