    Comparative analysis of the influence of R32 and R410A on APF of variable frequency air conditioner
    XU Zhiliang, XIONG Jun, CHEN Shaolin, LIU Deqing, LIU Canxian
    2018, 0(11):  22-23. 
    Abstract ( 404 )   PDF (1151KB) ( 700 )  
    References | Related Articles | Metrics
    According to R32 refrigerant correlation, the evaporation pressure and condensation pressure of R32 are 1.06 times and 1.03 times of R410A respectively. The unit cooling capacity of R32 is 1.52 times that of R410A. R32 is more efficient than R410A in the same refrigeration system. Through experimental verification 1.5 horse frequency conversion air conditioner, for example, the best filling quantity of R32 for about 75% of the R410A, throttle refrigeration system components need longer than R410A capillary, rated refrigerating performance comparison, the refrigerating capacity of the R32 than R410A 0.9% increased, the promotion of energy efficiency 4.7%. Compared with the rated heating performance, the heating capacity of R32 is 4.2% higher than that of R410A, and the energy efficiency is 3.6% higher. The heat produced at low temperature was 3.9% higher than R410A. Overall APF energy efficiency R32 is 2.5% higher than R410A. The copper wire motor used in the above air conditioning unit was changed into aluminum wire motor. The motor power was increased by 10W and the overall APF was 3.55. In terms of cost, aluminum wire motor is about 5 price cheaper than copper wire motor, so as to achieve the purpose of cost reduction, which provides a reference for the future development of R32 replacing R410A in variable frequency air conditioners.
    Study on R290 replacement of R134a in commercial ice maker matching
    HE Sifa, XU Yanhui, SUN Shijie, YAO Pingling
    2018, 0(11):  24-25. 
    Abstract ( 1409 )   PDF (1377KB) ( 761 )  
    References | Related Articles | Metrics
    By analyzing the properties of refrigerants, it is shown that R290 refrigerant has become the best choice for light commercial refrigeration. And through R290 and R134a ice machine test comparison, the R290 replace R134a in commercial ice machine application feasibility. At the same time, the reliability of using R290 refrigerant compressor was verified through experiments. This article has a certain guiding significance for ice maker manufacturers and compressor manufacturers.
    Special requirements for air conditioners using flammable refrigerant in standard IEC 60335-2-40: 2018
    WU Xiaoli, CAI Ning, HU Zhiqiang
    2018, 0(11):  26-33. 
    Abstract ( 849 )   PDF (1750KB) ( 2396 )  
    References | Related Articles | Metrics
    With the continuous application of flammable refrigerants in air conditioners, the safety of air conditioner with using flammable refrigerants has become a focus question in the industry. In order to help the relevant personnel to understand the standard, we have introduced the special requirement for flammable refrigerants appliance and analyzed how to meet the requirements in detail.
    Study on the structure improvement of propane refrigeration compressor air chamber
    QI Ji, PAN Chenguang, CHANG Xiangjun
    2018, 0(11):  34-36. 
    Abstract ( 204 )   PDF (2079KB) ( 234 )  
    References | Related Articles | Metrics
    As a typical own machinery, the compressor impeller efficiency and appropriate stator structure design has been paid close attention by the field. The focus on the fundamental goal is the flow losses, to reduce the energy consumption. The plethora of related research in recent years also can prove. The article simply analyses the propane refrigeration technology and process, and discusses in detail the propane refrigeration compressor of air chamber structure improvement design, numerical simulation, hope this can bring certain inspiration for professionals.
    Analysis of the application of R290 refrigerant in refrigeration equipment
    CAO Qinglin
    2018, 0(11):  37-39. 
    Abstract ( 277 )   PDF (1559KB) ( 935 )  
    References | Related Articles | Metrics
    With the increasing severity of global ozone layer destruction and climate warming, the application and development of refrigeration technology has attracted more and more attention from the international community. This paper first briefly introduces the application characteristics of R290 refrigerant, then analyses the design of R290 refrigeration system, and finally from the refrigerant to reduce refrigerant leakage and avoid leakage. The safety measures adopted in the design of refrigerators are discussed from the perspectives of aggregation, flammability and safety, reducing ignition and flammable sources, and strengthening the guidance of user correct use. It is hoped that these viewpoints can provide ideas for the popularization and application of R290 refrigerant.
    Design and research of room air conditioner with reheating dehumidification function
    LU Dongming, LU Yun
    2018, 0(11):  40-43. 
    Abstract ( 251 )   PDF (2431KB) ( 260 )  
    References | Related Articles | Metrics
    In order to meet the demand of "To keep the indoor temperature no declining during the dehumidification process", an air conditioner with the reheating dehumidifying function is developed. By comparing with the traditional weak cooling dehumidifying method, the reheating dehumidifying method is proved to be a practical and effective solution.
    Discussion on the application of OTA in household appliances
    SANG Tian, WU Jirong, ZHOU Ze
    2018, 0(11):  44-47. 
    Abstract ( 351 )   PDF (3194KB) ( 311 )  
    References | Related Articles | Metrics
    This paper studies the design and application of OTA (Over the Air Technology) in intelligent refrigerator with networking function. When the software development is completed, uploading the firmware version to the cloud server and regularly check and automatically upgrade the firmware version of the refrigerator through the electronic control board and Wi-Fi module, so as to make the running firmware version of the refrigerator remotely controlled. In the production process, refrigerators of different models can automatically download the corresponding electronic control software through the local server and the related module and then complete the upgrade and detection, because of this we can get high universality of the electronic control board at the manufacturing end and greatly improve the production efficiency. Meanwhile, based on OTA, the push of new technology on the sold machine can be realized, so that the new control technology of refrigerator can be continuously iterated on the stock machine, which improves the user stickiness of smart refrigerator and can create profits sustainably.
    Research on the realization scheme of the display control model for the glass cover of the automatic wave washing machine
    SONG Lijun, CHENG Baozhen, SUN Guangbin, ZHANG Kaihong, WANG Xiumei
    2018, 0(11):  48-53. 
    Abstract ( 307 )   PDF (5792KB) ( 353 )  
    References | Related Articles | Metrics
    Based on automatic pulsator washing machine display control module embedded in the glass cover models, these models can be according to the display control module in the upper cover divided into The putting in Mosaic position display control models of the side and The putting in back display control type two kinds, because the glass cover on a book cover in less space and display control module contains a lot of can't electric parts in contact with water or moisture, so the glass cover display control model on the cover of the linear way, way of assembling, sealing, and the maintenance cost is higher. In this paper, two kinds of realization schemes for the glass top cover display control model of the automatic wave wheel washing machine are discussed through the study of the overall planning of the glass top cover display control model of the automatic wave wheel washing machine.
    Design of refrigerant electric heater and its application in air conditioning
    MAO Yuehui
    2018, 0(11):  54-57. 
    Abstract ( 209 )   PDF (2365KB) ( 516 )  
    References | Related Articles | Metrics
    In this paper, a new type of air-conditioner electric heater with compact structure, high heating efficiency, good sealing ability and safe operation is designed. The technical problem of poor performance at low temperature is solved, and the function of quick frost at low temperature is realized. A set of experimental verification methods suitable for the safety application of refrigerant electric heaters is summed up, through the safety experiments of a large number of sample machines in different working conditions and various abnormal conditions. The results show that after the application of the cold medium electric heater, the prototype can be controlled at about 4min~8min compared with the conventional defrosting time. After the completion of the frosting, the air outlet can get hot air above 40 degrees centigrade. The heat of low temperature is improved and the comfort is good.
    Dropping simulation analysis in optimization of the split-type inner air-condition packaging
    LIU Xianwei, XIAO Xiao, ZHU Senwang, HE Zhi, HUI Shunli
    2018, 0(11):  58-63. 
    Abstract ( 251 )   PDF (5096KB) ( 269 )  
    References | Related Articles | Metrics
    Presently, with the rising cost of packaging materials, the profit of the household appliances is reduced. The optimization of the cushioning package structure is one of the effective ways to improve the competitiveness of the household appliance enterprises. In this paper, the CAE simulation technology is used to simulate and calculate a packaged of inner air-conditioner with over protection. The compression deformation of the foams and the parts of high failure risk of the product are found in the different falling conditions. The over protection parts and the unreasonable buffer structure parts of the foam are found. The structure of the foam are pertinence optimized and improved. Which is compared with the original scheme by simulation analysis and physical verification comparative analysis. The simulation results show that the optimization scheme is better protection and better product quality. Also, the optimization scheme reduces the overall size of the original scheme, reduces the material consumption by 23.7%, and reduces the cost of one unit by about 1.6 yuan.
    Vibration path analysis and vibration isolation study of floor fan
    ZHANG Gouyuan
    2018, 0(11):  64-66. 
    Abstract ( 356 )   PDF (2183KB) ( 258 )  
    References | Related Articles | Metrics
    Through structural analysis, vibration spectrum analysis and modal simulation analysis, the vibration transmission path of the shaking floor fan is obtained, and corresponding vibration isolation design is carried out for the path. Finally, through comparative analysis and hand-plate verification, it is confirmed that the low-frequency vibration isolation design of the wind blade can reduce the vibration amplitude of the screen cover 150μm~200μm. The maximum vibration amplitude of the whole machine can be decreased from 300μm to 80μm. The results show that the blade vibration isolation has obvious vibration reduction effect on the resonant vibration of floor fan, which can obviously alleviate the low-frequency resonance of floor fan and greatly improve the quality of the whole machine.
    Design of an automatic detection device for the bottom leakage of dishwasher
    CHEN Zan, Qi xin, WANG Xiang
    2018, 0(11):  67-69. 
    Abstract ( 277 )   PDF (1679KB) ( 266 )  
    References | Related Articles | Metrics
    An automatic detection device for bottom leakage of dishwasher is developed by using the principle of air pressure boosting. The device can realize on-line detection of bottom leakage of sink dishwasher, and has a series of advantages, such as high detection accuracy, reliable results, simple structure and convenient operation. It has produced very high economic benefits in production and application.
    Considerations on standard revision of safety for liquid heater
    GUO Yanping
    2018, 0(11):  70-71. 
    Abstract ( 161 )   PDF (1537KB) ( 114 )  
    References | Related Articles | Metrics
    Combined with standard revision of safety for liquid heater, this paper analyzes and discusses major differences between old and new versions, the test method and scope of application of some clauses are discussed in depth.
    Study on effects of refrigerated vehicles air-conditioning system with different fin spacing of evaporators
    WANG Jingya, GUO Ruian
    2018, 0(11):  72-74. 
    Abstract ( 259 )   PDF (1727KB) ( 505 )  
    References | Related Articles | Metrics
    Based on the analysis of the air-conditioning market of refrigerated vehicles in China, this paper briefly introduces the refrigeration principle of non-independent refrigerated vehicles air-conditioning system. Effects of different fin spacing of evaporators on the performance of the whole air condition system, evaporator drainage and heat transfer are experimentally investigated. The results show that the heat transfer performance of air side will be improved with the decrease of the fin spacing under the same experimental conditions, however, the drainage performance of the defrosting water may get worse. Therefore, the optimum fin spacing can effectively improve the performance of drainage and heat transfer of evaporators.
    Sweeping robot drop risk assessment and testing
    XIE Zhili, PEI Guangfu, WEI Mingran
    2018, 0(11):  75-77. 
    Abstract ( 524 )   PDF (1349KB) ( 214 )  
    References | Related Articles | Metrics
    According to the national standard of risk assessment and risk reduction and the safety requirements of household appliances, this paper discusses the method of risk assessment and the process of testing for sweeping robots, and verifies it by the drop test of sweeping robots under the guidance of the standard. By setting the fault to the ground sensor circuit and the collision sensor circuit, this paper simulates the falling situation, so that, it verifies the importance of risk assessment to the sweeping robot product.
    Interpretation of flow rate test method for electric fans at abroad
    LIU Hongtao, WU Wei
    2018, 0(11):  78-81. 
    Abstract ( 759 )   PDF (2055KB) ( 1210 )  
    References | Related Articles | Metrics
    This article interprets the IEC standard, and the methods for testing the air volume of fans in European, American, and Asian countries. Based on the IEC standard for electric fans, this paper compares the differences in the methods of testing air volume between different countries.
    Analysis of“GB 4706.12 Household and similar electrical appliances -Safety-Particular requirements for storage water heaters”standard revision
    YU Yang, LU Wei
    2018, 0(11):  82-85. 
    Abstract ( 611 )   PDF (1364KB) ( 700 )  
    References | Related Articles | Metrics
    The significance of compiling this paper lies in introducing and analyzing the main revisions of the upcoming version of the safety standard for storage water heaters, so as to enable enterprises to have a more detailed understanding of the main revisions of the standard in advance, so as to smoothly deal with the work of standard revision.
    Briefly discuss the importance of risk assessment in household appliance software evaluation
    WANG Changlin, WEI Mingran, PEI Guangfu
    2018, 0(11):  86-87. 
    Abstract ( 239 )   PDF (1140KB) ( 293 )  
    References | Related Articles | Metrics
    With the development of intelligent household appliances, electronic circuits are used in more and more products, most of which contain electronic controllers. The introduction of electronic circuit/software controller is a necessary condition for the development of household appliances in the direction of intellectualization, networking and centralized control. It also raises concerns about the effectiveness and reliability of electronic circuits and software. Software evaluation of household appliances has become an integral part of the certification process of smart appliances. This paper briefly introduces the importance of risk assessment in household appliance software evaluation.