家电科技 ›› 2025, Vol. 0 ›› Issue (zk): 472-475.doi: 10.19784/j.cnki.issn1672-0172.2025.99.098

• 第五部分 材料与零部件 • 上一篇    下一篇

高压差下电子膨胀阀失步问题研究

林森荣   

  1. 广东TCL智能暖通设备有限公司 广东中山 528427
  • 发布日期:2025-12-30
  • 作者简介:林森荣,机电高级工程师。研究方向:热泵性能。地址:广东省中山市园林路7号。E-mail:kt_linsr@tcl.com。

Research on the problem of electronic expansion valve out of step under high pressure difference

LIN Senrong   

  1. Guangdong TCL Intelligent HVAC equipment Co., Ltd. Zhongshan 528427
  • Published:2025-12-30

摘要: 膨胀阀作为空调系统的核心部件之一,其作用是调节制冷剂流量、降低制冷剂压力,使制冷剂满足空调系统负荷变化时的要求。然而传统的热力膨胀阀存在调节精度低、适应性差等问题,为了克服这些缺陷,电子膨胀阀应运而生。但电子膨胀阀也存在缺陷,例如机组在制冷、制热的高压差工况下,电子膨胀阀会出现失步问题,这不仅会影响机组的性能与能效,甚至可能导致系统压力过高,进而损坏压缩机。为解决这一问题,进行了实验分析并提出了相应的优化措施。结果表明:高压差工况下,制冷剂正向流向有利于提高电子膨胀阀控制精度;加强电子膨胀阀弹簧钢度可以提升阀门的响应速度和流量控制精度,降低阀失步概率。本研究对于解决空调系统电子膨胀阀失步问题具有一定的参考作用。

关键词: 空调系统, 电子膨胀阀, 采暖机, 阀失步

Abstract: As one of the core components of the air conditioning system, the expansion valve is used to regulate the refrigerant flow rate, reduce the refrigerant pressure, and meet the requirements of the air conditioning system when the load changes. However, traditional thermal expansion valves have problems such as low adjustment accuracy and poor adaptability. In order to overcome these shortcomings, electronic expansion valves have emerged. However, electronic expansion valves also have their own shortcomings. For example, under high pressure differential conditions of refrigeration and heating, the electronic expansion valve may experience out of step problems, which not only affects the performance and energy efficiency of the unit, but may even lead to excessive system pressure and damage to the compressor. To solve this problem, experimental analysis was conducted and corresponding optimization measures were proposed. The results indicate that under high pressure differential conditions, the forward flow of refrigerant is beneficial for improving the control accuracy of electronic expansion valves; Strengthening the stiffness of the electronic expansion valve spring can improve the response speed and flow control accuracy of the valve, and reduce the probability of valve out of step. This study has certain reference value for solving the problem of electronic expansion valve out of step in air conditioning systems.

Key words: Air conditioning system, Electronic expansion valve, Heating machine, Valve out of step

中图分类号: